Rotork: Keeping Data Centres Cool

How valve automation is supporting the shift to liquid cooling

Published: 11th November 2026 | Issue 108 Share article:

The rapid growth of artificial intelligence (AI), cloud computing and high-performance computing is transforming data centre design. As processor power and rack densities increase, operators face a growing challenge: removing ever-greater quantities of heat while maintaining uptime and controlling energy consumption.

To meet these demands, the industry is increasingly adopting liquid-cooling technologies. Unlike traditional air-cooled facilities, liquid-cooled data centres rely on precise coolant management throughout the cooling network. This is creating new opportunities for valve automation, particularly within cooling distribution units (CDUs) and server-level cooling systems, where flow control directly affects thermal performance, energy efficiency and system availability.

For Rotork, this shift represents a natural extension of technologies proven in mission-critical industries. The same demands for reliability, precision, rapid response and automation found in power generation, water treatment and oil & gas applications are becoming increasingly important in modern data centre cooling architectures.

Reliable Flow Control for CDUs

At the centre of many liquid-cooling systems are CDUs, which act as the interface between the facility's primary cooling system and the secondary circuits that cool individual server cabinets. CDUs regulate coolant circulation, temperature, pressure and filtration, making them critical to overall cooling performance.

Maintaining optimal conditions requires accurate valve control and rapid responsiveness to changing thermal loads. As AI servers and high-performance computing equipment create fluctuating cooling demands, even small variations in coolant flow can affect efficiency and cooling effectiveness.

Rotork's Hanbay M actuator range is used on primary flow control valves in CDU systems. Combining a compact footprint with fast response and high-resolution control, the actuators provide accurate modulation of coolant flow, helping operators maintain stable temperatures and precise operating conditions.

For bypass loop control valves, Noah SA and Hanbay M actuators provide reliable automated valve operation within increasingly compact CDU installations. Precise control of coolant flow can help reduce chiller load, improve power usage effectiveness (PUE) and lower overall energy consumption. Immediate response to Building Management System (BMS) signals allows cooling infrastructure to adapt automatically to changing conditions.

Coolant Control for Server Cabinets

As rack power densities continue to increase, effective thermal management within server cabinets becomes increasingly important. Modern liquid-cooling systems require accurate flow control, responsive temperature regulation and rapid isolation capabilities to maintain stable operating conditions as computing loads fluctuate.

Rotork's ePIV, Hanbay M and Noah SA solutions help support these requirements through precise flow control and valve automation. ePIV control valves combine integrated electromagnetic flow measurement with onboard control functionality, enabling accurate flow control independent of pressure conditions. This allows cooling systems to respond rapidly to changing demand while maintaining consistent thermal performance throughout the cooling circuit.

Hanbay M actuators support both rapid isolation and precision temperature control within cabinet cooling systems. Used on coolant inlet isolation valves and pressure independent control valves (PICVs), they provide fast response to changing thermal conditions while maintaining accurate temperature setpoints throughout the cabinet. Controlled valve movement also helps minimise the risk of water hammer.

Noah SA actuators provide compact and dependable valve automation for cabinet-level cooling applications. Together, ePIV, Hanbay M and Noah SA technologies help operators improve thermal management, optimise cooling efficiency and meet the increasing demands of high-density computing environments. 

Fast Response Leak Isolation at Server Level

The growing adoption of direct-to-chip cooling is bringing liquid coolant ever closer to processors and other high-value assets. As a result, resilience and availability are becoming just as important as cooling performance.

Modern liquid-cooling architectures increasingly incorporate localised flow control and protection at server level. In these applications, a coolant leak can have significant operational and financial consequences, making rapid isolation essential.

Dedicated inlet and outlet valves can be installed on individual server trays, enabling affected systems to be isolated quickly without impacting neighbouring equipment. Upon leak detection, a signal from the Building Management System can trigger immediate valve closure, helping operators respond without delay.

Hanbay M actuators can achieve fast valve isolation in approximately one second, helping operators contain leaks before they affect neighbouring equipment. Fast isolation reduces the risk of damage, minimises downtime and allows unaffected servers to continue operating while maintenance activities are carried out.

Supporting the Future of Liquid-Cooled Data Centres

As AI workloads continue to drive higher rack densities and greater cooling demands, effective liquid cooling will depend on more than just pipes, pumps, and heat exchangers. Success will increasingly rely on precise, responsive and reliable valve automation.

For operators deploying cooling systems, technologies such as Hanbay M, Noah SA and ePIV demonstrate how flow control can improve thermal management, reduce energy consumption and enhance system resilience. From controlling primary flow and bypass valves within CDU systems to supporting cabinet-level cooling and protecting high-value servers through rapid leak isolation, advanced valve automation is becoming a key enabler of reliable, efficient and resilient data centre infrastructure.