Actuators to the Rescue
Engineering Valve Automation for Extreme Environments

Martin Hardwidge, Key Account Manager, AUMA Actuators Limited
Valve automation is often taken for granted. Yet in some of the world’s most demanding operating environments, electric actuators become mission-critical devices, required to perform reliably in conditions ranging from Arctic temperatures and desert heat to submerged installations, explosive atmospheres, nuclear facilities and naval vessels.
The engineering challenge is not simply making an actuator work. It is ensuring predictable performance throughout its service life, regardless of the environment.
Modern electric actuators are sophisticated electromechanical systems incorporating motors, gearing, electrical circuitry, positioning systems, displays and electronic controls. Each component can be affected by its surroundings, so engineering for extreme conditions extends far beyond the external enclosure.
Engineering for extremes
Temperature illustrates the challenge. While a typical electric actuator is designed for operation between -40°C and +70°C, specialist applications can demand operation down to -60°C or exposure to ambient temperatures approaching 120°C. Meeting these requirements can involve different motor insulation, lubricants, heaters, switches, connectors and sealing materials.
Submerged applications present different demands. Double-sealed construction, specialised cable glands and assemblies, solid drive shafts and purpose-designed valve attachments can all be required to maintain integrity underwater.
In potentially explosive atmospheres, actuator design must ensure the equipment does not become an ignition source. Flameproof (Ex d) protection contains heat generated by an internal explosion, while Increased Safety (Ex e) protection minimises the possibility of arcs, sparks and excessive temperatures under specified conditions.
Requirements become even more demanding in nuclear and naval applications. Nuclear qualification can include radiation exposure exceeding 1.05 × 10⁶ Gy, thermal ageing simulating a 60-year operational life and earthquake testing. Naval actuators can face corrosion, space and acoustic constraints as well as extreme shock loading – potentially around 180g on surface vessels and up to 400g aboard submarines.
Engineering beyond the specification
There is no universal actuator solution for extreme environments. Successful engineering depends on understanding how thermal, mechanical, chemical and operational conditions affect individual components, then configuring the complete system accordingly.
As operational resilience becomes increasingly important, actuator selection is therefore about more than torque and speed. For engineers specifying valve automation, it means selecting equipment designed, configured and proven for the environment in which it must operate - not simply the valve it is intended to drive.

| Telephone: | 01275 871141 |
| Email: | mail.uk@auma.co.uk |
| Website: | www.auma.co.uk |
| More information on the AUMA Actuators Ltd BVAA Member Directory Page |
Search related valve / actuator articles: AUMA Actuators LtdIssue 108Electric Actuators